FREQUENCY AND TACHO METER >> TE FREQUENCY AND TACHOMETE >> TE FREQUENCY AND TACHO METER

FEATURES

1.It can measure frequency tacho line speed meter
2.EEPROM back up system
3.High-accuracy,measuring field:0.1Hz-20KHz
4. All the function can operate from the panel key
1. ORDERING CODE
2. MODEL AND SPECIFICATIONS
Model Setting stage Display range Measuring field Input signal Measuring
TE-R48P41B 1 Stage 0.001-9999 0.1Hz-20KHz 4-30V 0.02%rdg¡À3Digit
TE-R72P41B 1 Stage 0.001-9999 0.1Hz-20KHz 4-30V 0.02%rdg¡À3Digit
TE-R49P62A 2 Stage 0.00001-999999 0.1Hz-20KHz 4-30V 0.02%rdg¡À3Digit
3.SPECIFICATIONS
power voltage AC220V¡À10% 50/60Hz
consumption ¡Ü5VA (at AC 220V 50Hz)
display range 6 digit:0.00001-999999 4 digit:0.001-9999
Measuring field 0.1Hz-20KHz
input signal touch input,collector input,sensor input,input resistance 5K¦¸,low calm 0-2V,high calm 4-30V
Measuring 0.02%rdg¡À3Digit (mult=1 div=1)
over flow When measuring £¦#118alue came 6 digit,display"------"
reposition mode hand repositon¡¢self repostion¡¢outside add signal repostion
output mode N ¡¢F¡¢ ¡¢C¡¢ R
assustabt voltage DC 12V¡À10% 50mA max
Insulation intension Between lead electric end and bare very using metal,not connect touch
Insulation strength AC2000V,50Hz/60Hz 1min(Between lead electric end and bare very using metal,not connect touch)
anti-jamming Use noise anti-jammingsirnulatorside wave disturb:+2KV(betweenpower end)¡¢+500V(beteween input end)
work condition 0-50¡æ 45%-85%RH
4.CONNECTION DIAGRAM
5.THE OUTSIDE DIMENSION
6. CAUTIONS
1.The meter must be heating 15 minutes with the power on before use.
2.Use in ambient temperatures of 0¡æ to 40¡æ,humidifies of 85% R.H.
3.The meter alignment interval time is one year.
4.If the input signal is superimposed with high-frequency noise,use a High-pass filter in the input signal line.
5.Input wire should not be too long. If measured signal and meter is long, please use a 2-core shielded cable, and connect its outer shite to the LO side at a signal soure.
6.If the digit meter relay is not used for a long time. Please counect power supply once every three months, not less
than 4 hours each time.