TEMPERATURE CONTROL >> TE-T TEMPERATURE CONTROLLER >> TE-T TEMPERATURE CONTROLLER

FEATURES

1.Input select K,E,S,B,Pt100,Cu50
2.PID autotuning to controll output
3.Software mix zero mix full degree,cold end measuring signal-harded,an amplifier stable zero self,display percision excellent out of 0.2%FS
4.Controll output be selected by relay、SCR、voltage or ampere
1. ORDERING CODE
2.MODEL AND SPECIFICATION
1.TC Measuring Range
Model Sensor Measuring Resolution Accuracy
TE-T□K □ K 0℃~1300℃ 1℃ ±0.5%F.S±1digit
TE-T□E □ E 0℃~800℃ 1℃ ±0.5%F.S±1digit
TE-T□S □ S 0℃~1600℃ 1℃ ±0.5%F.S±1digit
TE-T□S □ B 0℃~1800℃ 1℃ ±0.5%F.S±1digit
2.RTD Measuring Range
Model Sensor Measuring Resolution Accuracy
TE-T□P □ Pt100 -200℃~600℃ 0.1℃ ±0.5%F.S±1digit
TE-T□C □ Cu50 -50℃~150℃ 0.1℃ ±0.5%F.S±1digit
3.Analog Input
Model Sensor Measuring Resolution Accuracy
TE-T□V □ 0~5V/1~5V -1000~9999 由量程确定 ±0.5%F.S±1digit
TE-T□A □ 4~20mA/1~10mA -1000~9999 由量程确定 ±0.5%F.S±1digit
3. SPECIFICATIONS
cold end compensate error ≤±2℃
measuring number display range -1999~9999199~999 two kinds
alarm rang full setting freelye
Display red green double-color row number tube
lectric equipent output touch dot capacity 3A/220V block nature or select
can control gui touch off signal 5V/40us or forehead 100mA at once 1A(from touch off)
solid electric equipent output signa 12V±3V 30mA
wrok circumstancesmu 0~50℃,mutural humidity≤85%RH
Power AC 220V±10% 50HZ/60HZ
Power consumption ≤4VA
4.CONNECTION DIAGRAM
attention:all the connection picture OUT indicating unit ,the switchcondition indicates output condition with electric equipment ,+ - condition indicates continuing electric current ,voltage output end and connecting the solid electric equiment'pulse DC voltage end,when connect SI output ,-end connect SI touch off end,+end connect SI one positivepole (or the sigle SI negative pole),the main controlling output connection wire picture as below:
5.THE OUTSIDE DIMENSION